INTERZINC 315 PDF

Interzinc B. Storage Conditions: All painting materials shall be stored in a clean, dry, well ventilated place, protected from sparks, flame. A three component, metallic, zinc rich epoxy primer which passes Slip B coefficient. Interzinc B complies with SSPC Paint 20 and contains minimum 80%. Interzinc Call for Price. A two component high solids, low VOC metallic zinc- rich epoxy primer formulated on proprietary polymer technology which provides.

Author: Nagul Vudoktilar
Country: Switzerland
Language: English (Spanish)
Genre: Environment
Published (Last): 5 December 2008
Pages: 71
PDF File Size: 14.49 Mb
ePub File Size: 20.18 Mb
ISBN: 261-9-45346-244-5
Downloads: 52591
Price: Free* [*Free Regsitration Required]
Uploader: Voodoosar

No coating material may be procured or delivered to the project site prior to the review and acceptance of the proposed materials by the Architect in writing. Commencement of application is acceptance of substrate. The following is one example of how a mock-up on a large project might be specified. Do not apply coatings under environmental conditions outside manufacturer’s absolute limits.

For each finish product specified, two complete sets of color chips representing manufacturer’s full range of available materials. International Paint has operations in 54 countries worldwide and over 3, employees. Store and dispose of hazardous materials, and materials contaminated by hazardous materials, in accordance with requirements of local interziinc having jurisdiction. Store materials in strict accordance with intsrzinc documented instructions.

Interior environment with high humidity and exposure to air pollution. Provide a mock-up for evaluation of surface preparation techniques and application workmanship. Apply finish coat in accordance with the manufacturer’s application instructions. Upon completion of installation, all excess material, overspray and debris must be cleared and removed from the job site. Submit manufacturer documentation that the fireproofing product complies with the specified contract requirements.

Grind smooth all weld spatter and defects prior to commencement of coating application. Pipes, ducts, conduits, hangers and supports, equipment, and equipment enclosures exposed to view in all rooms and spaces except mechanical rooms, electrical rooms, and utility rooms. Areas will be designated by the Architect.

  DLBM-CH120 APPLICATION PDF

SECTION HIGH PERFORMANCE SPECIALTY COATINGS

Primer applied off site must be in accordance with the provisions of Section Deliver materials in manufacturer’s original, sealed, undamaged container with identification label intact. Surfaces Not to be Painted: International Protective Coatings is the leading supplier of high performance Protective Coatings and forms part of Akzo Nobel, a market driven, technology based interzicn specializing in Coatings, Chemicals and Pharmaceuticals.

Protect adjacent areas from over spray of coating material. Company specializing in applying the work of this section with a minimum of three 3 onterzinc documented experience and certified by the manufacturer. Steel substrate temperature shall be a minimum of 5 deg F 3 deg C above the dew point of the surrounding air for a period of 24 hours prior and during the application of the material.

Provide ventilation in areas to receive work of this section during application and minimum 24 hours after application. A inrerzinc of the transport document and manufacturers conformance certificate shall be attached to the material delivery QC form.

Interzinc – A k i r a

Requests for substitutions must be made 30 days prior to submittal and contain the full name of each product, descriptive literature, testing data collected from industry consensus standard testing, data on past performance, manufacturer’s instruction for use and generic inteerzinc. Do not commence adjacent or adjoining Work until the application of the coatings is complete in that area.

For each finish product specified, two samples representing actual inetrzinc, color, and finish. Verify that substrate and workspace temperature and humidity conditions are in accordance with requirements 3155 this section. The Manufacturer’s quality management system must be assessed and registered by an independent registrar as conforming to the requirements of ISO Maintain environmental conditions temperature, humidity, and ventilation within limits recommended by manufacturer for optimum results.

Submit product intezinc including manufacturer’s technical information indicating product performance characteristics, performance and limitation criteria. Apply material at the required dry film thickness. At project closeout, provide to Owner or Owners Representative an executed copy of the manufacturer’s standard limited warranty against manufacturing defect, outlining its terms, conditions, and exclusions from coverage.

  ISABEL CARMONA ECUACIONES DIFERENCIALES PDF

Provide primer cut back areas a minimum three 3 inches 76mm from bolted connections and minimum twelve 12 inches mm from welded connections.

Interzinc 315

Retain only coating systems specified and delete all others. To be selected by Architect from manufacturer’s full range of available colors.

The relative humidity of the application area shall not exceed a maximum of 85 percent for 24 hours prior, during and 24 hours after the application of the material.

Submit plan, section, elevation and perspective drawings as necessary to depict system configuration, design considerations and application procedures. All products listed in this section must be manufactured under the appropriate follow-up service with each container bearing the certified label mark. Do not commence application of coatings until the contractor, applicator and inspector have examined the surfaces to receive Work in this section, and determined that the surfaces are acceptable to receive the specified materials.

Interior chemical iinterzinc areas and swimming pools. Final color, gloss intrzinc finish will be determined and approved by the Architect. Delete the next paragraph if not applicable. Structural steel and framing with reference to primer receiving fire protection materials. Substrate and air temperature shall be in accordance with the manufacturers requirements. International Paint, LLC, which is located at: Protect work area from windblown dust and rain. Marine, offshore and coastal areas with high salinity.

Clean substrate free of dust, dirt, grease or other foreign substances that would impair the bond of the coating. Submit manufacturer’s written installation instructions.