DIN 40050-9 FREE PDF

The IP Code, International Protection Marking, IEC standard , sometimes interpreted as . The letter K is specified in DIN , and not in IEC With their absolutely edge-free design these motors reduce the costs for machine manufacturers Protection class, IP 69K (at 30 bar, refering to DIN ). IP69K, Tested in accordance with DIN /Part 9 IP6k9k. 32A, V ac/dc IP69k to DIN free of dust, grease or any other contamination. 4.

Author: JoJolkree Tar
Country: Peru
Language: English (Spanish)
Genre: Photos
Published (Last): 11 June 2017
Pages: 83
PDF File Size: 14.51 Mb
ePub File Size: 20.40 Mb
ISBN: 290-3-96551-990-9
Downloads: 28654
Price: Free* [*Free Regsitration Required]
Uploader: Tojora

Further letters can be appended to provide additional information related to the protection of the device:.

X means there is no data available to specify a protection rating with regard to one of the criteria. Views Read Edit Dun history. Retrieved from ” https: Larger specimens are mounted upright, no turntable required, and are tested freehand for at least 3 minutes at distance of 0. There are no hyphens in a genuine IP code. The first digit indicates the level of protection that the enclosure provides against access to hazardous parts e. By IEC added level 9 water ingress testing, with IPx9 being essentially the same spray test as IP69K, also adding a drawing of a fixture to verify the water pressure.

di

Water projected by a nozzle 6. Test a is conducted for 10 minutes. Similarly, an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which feee is exposed to vertically or nearly vertically dripping water. National Electrical Manufacturers Association.

The same requirements apply here as to the stainless steel servomotors. All articles with unsourced statements Articles frwe unsourced statements from July Commons category link is on Wikidata.

The AM stainless steel servomotors are fully compatible with the high requirements in the food, beverage and pharmaceutical industries with respect to optimum cleaning, resistance to aggressive cleaning agents, heavy mechanical loads and adverse environmental conditions. The equipment is suitable for continuous immersion in water under conditions which shall dij specified by the manufacturer.

In other projects Wikimedia Commons.

  ICT 2 TELEVES PDF

IP67, IP68 & IP69K environmentally sealed circular power connectors

This often includes drawings specifying the required test equipment, such as the shape of water nozzles used for water jet testing. The digits indicate conformity with the conditions summarized in the tables below.

Wikimedia Commons has media related to IP code. Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either: NEMA ratings also require additional product features and tests such as functionality under icing conditions, enclosures for hazardous areasknock-outs for cable connections and others not addressed by IP ratings.

A vacuum must be applied. One must refer to the latest revision of the required standard when conducting tests for agency certification. The test depth and duration is expected to be greater than the requirements for IPx7, and other environmental effects may be added, such as temperature cycling before immersion. The standard aims to provide users more detailed information than vague marketing terms such as waterproof.

Retrieved 10 January However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. IP22 or IP2X are typical minimum requirements for the design of electrical accessories for indoor use. The digit 0 is used where no protection is provided. Test duration of up to 8 hours based on air flow.

Smaller specimens rotate slowly on a turntable, from 4 specific angles. For example, a cellular phone rated at IP68 is “dust resistant” and can be “immersed in 1. Not to be confused with IP address or Intellectual property. The System of Tests and Meaning of Codesarchived from the original on All gearbox materials that come into contact with the environment exhibit high resistance to a large number of aggressive CIP Cleaning in Place cleaning media.

No ingress of dust; complete protection against contact dust tight. Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment.

Additional standards are often referenced that may contain important information.

Ingress Protection IP69K (DIN 40050-9 – IEC EN 60529)

A device which dln both tests is indicated by listing both tests separated by a slash, e. The second digit indicates the level of protection that the enclosure provides against harmful ingress of water.

  ANSI TIA EIA 606A PDF

Test b is conducted with shield in place for 5 minutes minimum. Ratings between the two standards are not directly equivalent: Water projected in powerful jets 6. The IP CodeInternational Protection MarkingIEC standardsometimes interpreted as Ingress Protection Markingclassifies and rates the degree of protection provided against intrusion body parts such as hands and fingersdustaccidental contact, and water frde mechanical casings and electrical enclosures.

The equivalent European standard is EN IPX-8 for example is thus an invalid IP code. Dripping water vertically falling drops shall have no harmful effect on the specimen when mounted in an upright position onto a turntable and rotated at 1 RPM.

With the availability of portable devices, and the desire to get outside with fre lifestyles, portable speakers have become popular with the rugged consumer market for those who enjoy outdoor recreationextreme sports as well. A Hygienic Design drive axis does not always end at the stainless steel shaft of the motor; the use of a gearbox is often absolutely necessary.

AG Planetary gear units for AM stainless steel servomotors The AM stainless steel servomotors are fully compatible with the high requirements in the food, beverage and pharmaceutical industries with respect to optimum cleaning, resistance to aggressive cleaning agents, heavy mechanical loads and adverse environmental conditions.

Test b is conducted without shield for dln minutes minimum. The digit is replaced with the letter X when insufficient data has been gathered to assign a protection level. The IPx9 specification in IEC has details for testing larger specimens frde will not fit on a turntable test fixture see table above. The inclusion of an Ingress Protection rating has become increasingly common for use in the consumer electronics market with devices such as mobile phonestablet computers and cameras now being sold as water resistant, waterproof and dustproof.